Scope: UAV- Unmanned Aerial Vehicle base Laser Scan point Clouds.
Inputs: Laser Scan Data. (Dummy Model)
Built up Area: 500 sqm.
Revit Version: 2020.
LOD: 300.
Out Puts: Revit 3D Model.
Description:
- All content detailed
- All services to be identified as “Hydronic Supply” System type – allowing for edit by JEG.
- Template to be provided – Revit families to be used.
- No model elements on “Unassigned” or ”Default” or “Undefined”
- No model in place elements
- All Systems to have continuity (be connected from origin to end)
- Straight lines of pipe to be detailed as such, not broken into multiple shorter lengths.
- Connectors (elbows, flanges, etc) to be connected and on Hydronic Supply.
- Clash free model
- Structural – detail based on size within Point Cloud. Choose the lowest strength of options available.